PT-2012-5351 · Sielco Sistemi · Winlog Pro Scada+1
CVSS v2.0
9.3
عالية
| المتجه | AV:N/AC:M/Au:N/C:C/I:C/A:C |
Name of the Vulnerable Software and Affected Versions
Sielco Sistemi Winlog Pro SCADA versions prior to 2.07.17
Sielco Sistemi Winlog Lite SCADA versions prior to 2.07.17
Description
The issue allows remote attackers to execute arbitrary code via a crafted TCP packet on port 46824. This is achieved by sending a packet with a crafted positive integer after the opcode, which triggers incorrect function-pointer processing and can lead to a buffer overflow.
Recommendations
For Sielco Sistemi Winlog Pro SCADA versions prior to 2.07.17, update to version 2.07.17 or later.
For Sielco Sistemi Winlog Lite SCADA versions prior to 2.07.17, update to version 2.07.17 or later.
استغلال
إصلاح
وجدت خطأً في الوصف؟ لديك ما تضيفه؟ لا تتردد في مراسلتنا 👾
تصنيف نقاط الضعف
المعرّفات ذات الصلة
المنتجات المتأثرة
Winlog Lite Scada
Winlog Pro Scada