PT-2012-5356 · Sielco Sistemi · Winlog Pro Scada+1
CVSS v2.0
9.3
عالية
| المتجه | AV:N/AC:M/Au:N/C:C/I:C/A:C |
Name of the Vulnerable Software and Affected Versions
Sielco Sistemi Winlog Pro SCADA versions prior to 2.07.18
Sielco Sistemi Winlog Lite SCADA versions prior to 2.07.18
Description
The issue is related to the lack of validation of the return value of the
realloc function, which can be exploited by remote attackers. This can be achieved by sending a crafted TCP packet to port 46824 with a negative integer after the opcode, potentially causing a denial of service due to an invalid 0x00 write operation and daemon crash. There may be other unspecified impacts.Recommendations
For Sielco Sistemi Winlog Pro SCADA versions prior to 2.07.18, update to version 2.07.18 or later.
For Sielco Sistemi Winlog Lite SCADA versions prior to 2.07.18, update to version 2.07.18 or later.