PT-2014-6174
CVE-2014-4863
·
تاريخ النشر
2014-09-05
·
تاريخ التحديث
2014-09-08
الوصف من
CVSS 2.0
5.0
متوسطةالمقاييسAV:N/AC:L/Au:N/C:P/I:N/A:N
Name of the Vulnerable Software and Affected Versions
Arris Touchstone DG950A cable modem version 7.10.131
Description
The issue allows remote attackers to obtain sensitive information, including password, key, and SSID details, by sending an SNMP request. This is possible due to the use of a default SNMP community string set to
public.Recommendations
For Arris Touchstone DG950A cable modem version 7.10.131, consider changing the default SNMP community string to a secure value to prevent unauthorized access. As a temporary workaround, restrict access to the SNMP service to minimize the risk of exploitation.