PT-2017-18571
CVE-2017-8841
·
تاريخ النشر
2017-06-05
·
تاريخ التحديث
2017-08-13
الوصف من
CVSS 3.1
8.1
عاليةالمقاييسAV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H
Name of the Vulnerable Software and Affected Versions
Peplink Balance devices (305, 380, 580, 710, 1350, and 2500) with firmware before 7.0.1-build2093
Description
The issue is related to arbitrary file deletion. It is caused by an absolute path traversal in the "cgi-bin/MANGA/firmware process.cgi" endpoint via the
upfile.path parameter.Recommendations
For Peplink Balance devices (305, 380, 580, 710, 1350, and 2500) with firmware before 7.0.1-build2093, update the firmware to version 7.0.1-build2093 or later to resolve the issue. As a temporary workaround, consider restricting access to the "cgi-bin/MANGA/firmware process.cgi" endpoint to minimize the risk of exploitation. Avoid using the
upfile.path parameter in the affected endpoint until the issue is resolved.قابلية الاستغلال
استغلال
إصلاح
التأثيرات
الباحثون
المورّدون
المنتجات المتأثرة
وجدت خطأً في الوصف؟ لديك ما تضيفه؟ لا تتردد في مراسلتنا 👾