PT-2020-1751
CVE-2019-5140
·
تاريخ النشر
2020-02-25
·
تاريخ التحديث
2022-06-13
الوصف من
CVSS 2.0
9.0
عاليةالمقاييسAV:N/AC:L/Au:S/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions
Moxa AWK-3131A firmware version 1.13
Description
The issue exists due to the lack of neutralization of special elements used in an operating system command. This allows for a command injection vulnerability in the iwwebs functionality, where a specially crafted diagnostic script file name can cause user input to be reflected in a subsequent
iwsystem call. As a result, an attacker can gain remote control over the device by sending commands while authenticated as a low-privilege user.Recommendations
For Moxa AWK-3131A firmware version 1.13, consider disabling the
iwsystem call or restricting access to the diagnostic script functionality until a patch is available. Additionally, limit the privileges of low-privilege users to minimize the risk of exploitation. At the moment, there is no information about a newer version that contains a fix for this vulnerability. وجدت خطأً في الوصف؟ لديك ما تضيفه؟ لا تتردد في مراسلتنا 👾