PT-2020-8612
CVE-2018-16994
·
تاريخ النشر
2020-02-18
·
تاريخ التحديث
2020-08-24
الوصف من
CVSS 2.0
7.8
عاليةالمقاييسAV:N/AC:L/Au:N/C:N/I:N/A:C
Name of the Vulnerable Software and Affected Versions:
PHOENIX CONTACT AXL F BK PN versions 1.0.4 and earlier
PHOENIX CONTACT AXL F BK ETH versions 1.12 and earlier
PHOENIX CONTACT AXL F BK ETH XC versions 1.11 and earlier
Bosch Rexroth S20-ETH-BK (affected versions not specified)
Bosch Rexroth S20-PN-BK+ (affected versions not specified)
Description:
The issue allows remote attackers to initiate a complete lock up of the bus coupler due to incorrect handling of a request with non-standard symbols. No authentication of the request is required.
Recommendations:
For PHOENIX CONTACT AXL F BK PN versions 1.0.4 and earlier, update to a version later than 1.0.4.
For PHOENIX CONTACT AXL F BK ETH versions 1.12 and earlier, update to a version later than 1.12.
For PHOENIX CONTACT AXL F BK ETH XC versions 1.11 and earlier, update to a version later than 1.11.
For Bosch Rexroth S20-ETH-BK and S20-PN-BK+, contact the vendor for specific guidance on updating or mitigating the issue.
As a temporary workaround, consider restricting access to the bus coupler to minimize the risk of exploitation.
وجدت خطأً في الوصف؟ لديك ما تضيفه؟ لا تتردد في مراسلتنا 👾