PT-2020-9800
CVE-2019-16213
·
تاريخ النشر
2020-06-25
·
تاريخ التحديث
2020-07-01
الوصف من
CVSS 2.0
9.0
عاليةالمقاييسAV:N/AC:L/Au:S/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions
Tenda PA6 Wi-Fi Powerline extender version 1.0.1.21
Description
The issue allows a remote authenticated attacker to execute arbitrary commands on the system. This can be achieved by sending a specially crafted string to modify the device name of an attached PLC adapter, thereby injecting and executing arbitrary commands on the system with root privileges.
Recommendations
For Tenda PA6 Wi-Fi Powerline extender version 1.0.1.21, consider restricting access to the device to prevent remote authenticated attacks until a patch is available. As a temporary workaround, avoid using the device name modification feature for attached PLC adapters to minimize the risk of exploitation. At the moment, there is no information about a newer version that contains a fix for this vulnerability.
وجدت خطأً في الوصف؟ لديك ما تضيفه؟ لا تتردد في مراسلتنا 👾