PT-2021-5504
CVE-2021-33271
·
تاريخ النشر
2021-01-12
·
تاريخ التحديث
2021-12-03
الوصف من
CVSS 3.1
10
حرجةالمقاييسAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions
D-Link DIR-809 devices with firmware through DIR-809Ax FW1.12WWB03 20190410
Description
A stack buffer overflow issue was found in the
sub 80046EB4 function in the /formSetPortTr endpoint. This issue can be triggered via a crafted POST request, potentially allowing a remote attacker to execute arbitrary code in the system.Recommendations
For D-Link DIR-809 devices with firmware through DIR-809Ax FW1.12WWB03 20190410, consider disabling the
sub 80046EB4 function in the /formSetPortTr endpoint as a temporary workaround until a patch is available. Restrict access to the /formSetPortTr endpoint to minimize the risk of exploitation. Avoid using crafted POST requests to the /formSetPortTr endpoint until the issue is resolved. At the moment, there is no information about a newer version that contains a fix for this vulnerability.قابلية الاستغلال
استغلال
التأثيرات
الباحثون
المورّدون
المنتجات المتأثرة
وجدت خطأً في الوصف؟ لديك ما تضيفه؟ لا تتردد في مراسلتنا 👾