PT-2023-18499
CVE-2023-22441
·
تاريخ النشر
2023-05-10
·
تاريخ التحديث
2025-01-28
الوصف من
CVSS 3.1
8.6
عاليةالمقاييسAV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H
Name of the Vulnerable Software and Affected Versions
Seiko Solutions SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier
Seiko Solutions SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier
Description
A missing authentication issue for a critical function exists in the Seiko Solutions SkyBridge series, allowing a remote attacker to obtain or alter the product's setting information or execute critical functions without authentication, such as rebooting the product.
Recommendations
For Seiko Solutions SkyBridge MB-A200 firmware Ver. 01.00.05 and earlier, update to a version later than Ver. 01.00.05 to resolve the issue.
For Seiko Solutions SkyBridge BASIC MB-A130 firmware Ver. 1.4.1 and earlier, update to a version later than Ver. 1.4.1 to resolve the issue.
As a temporary workaround, consider restricting access to critical functions that do not require authentication until a patch is available.