Name of the Vulnerable Software and Affected Versions SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) versions prior to V3.5.20 SIMATIC CP 1243-1 (incl. SIPLUS variants) versions prior to V3.5.20 SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) versions prior to V3.5.20 SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) versions prior to V3.5.20 SIMATIC CP 1243-7 LTE versions prior to V3.5.20 SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) versions prior to V3.5.20 SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (affected versions not specified) SIMATIC IPC DiagBase (affected versions not specified) SIMATIC IPC DiagMonitor (affected versions not specified) SIMATIC WinCC Runtime Advanced (affected versions not specified) SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) versions prior to V2.4.8 TIM 1531 IRC (6GK7543-1MX00-0XE0) versions prior to V2.4.8
Description A vulnerability has been identified in the web server of the affected devices, which do not properly handle shutdown or reboot requests. This could lead to the cleanup of certain resources, allowing a remote attacker with elevated privileges to cause a denial of service condition in the system.
Recommendations For SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) versions prior to V3.5.20, upgrade to version V3.5.20 or later. For SIMATIC CP 1243-1 (incl. SIPLUS variants) versions prior to V3.5.20, upgrade to version V3.5.20 or later. For SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) versions prior to V3.5.20, upgrade to version V3.5.20 or later. For SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) versions prior to V3.5.20, upgrade to version V3.5.20 or later. For SIMATIC CP 1243-7 LTE versions prior to V3.5.20, upgrade to version V3.5.20 or later. For SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) versions prior to V3.5.20, upgrade to version V3.5.20 or later. For SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) versions prior to V2.4.8, upgrade to version V2.4.8 or later. For TIM 1531 IRC (6GK7543-1MX00-0XE0) versions prior to V2.4.8, upgrade to version V2.4.8 or later. At the moment, there is no information about a newer version that contains a fix for SIMATIC HMI Comfort Panels, SIMATIC IPC DiagBase, SIMATIC IPC DiagMonitor, and SIMATIC WinCC Runtime Advanced.
قابلية الاستغلال
إصلاح
التأثيرات
المورّدون
المنتجات المتأثرة
تصنيف نقاط الضعف
المعرّفات ذات الصلة
وجدت خطأً في الوصف؟ لديك ما تضيفه؟ لا تتردد في مراسلتنا 👾