PT-2012-1979
CVE-2011-4876
·
Publicado
2012-02-03
·
Atualizado
2017-08-29
Descrição por
CVSS 2.0
9.3
AltaMétricasAV:N/AC:M/Au:N/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions
Siemens WinCC flexible versions 2004 through 2008
Siemens WinCC V11 (aka TIA portal)
Siemens TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels
Siemens WinCC V11 Runtime Advanced
Siemens WinCC flexible Runtime
Description
The issue allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string when Transfer Mode is enabled. This is due to a directory traversal vulnerability in HmiLoad in the runtime loader.
Recommendations
For Siemens WinCC flexible versions 2004 through 2008, disable Transfer Mode to prevent exploitation.
For Siemens WinCC V11 (aka TIA portal), disable Transfer Mode to prevent exploitation.
For Siemens TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels, disable Transfer Mode to prevent exploitation.
For Siemens WinCC V11 Runtime Advanced, disable Transfer Mode to prevent exploitation.
For Siemens WinCC flexible Runtime, disable Transfer Mode to prevent exploitation.