PT-2012-5352
CVE-2012-4355
·
Publicado
2012-08-19
·
Atualizado
2012-08-20
Descrição por
CVSS 2.0
9.3
AltaMétricasAV:N/AC:M/Au:N/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions
Winlog Pro SCADA versions prior to 2.07.18
Winlog Lite SCADA versions prior to 2.07.18
Description
The issue allows remote attackers to execute arbitrary code via a crafted TCP packet sent to port 46824, containing a negative integer after the opcode. This triggers incorrect function-pointer processing, potentially leading to a buffer overflow.
Recommendations
For Winlog Pro SCADA versions prior to 2.07.18, update to version 2.07.18 or later.
For Winlog Lite SCADA versions prior to 2.07.18, update to version 2.07.18 or later.
Explorabilidade
Exploit
Correção
Pesquisadores
Fornecedores
Produtos afetados
Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾