PT-2015-4047

CVE-2014-8479

·

Publicado

2015-01-21

·

Atualizado

2020-02-10

Descrição por

CVSS 2.0
6.8
Média
MétricasAV:N/AC:L/Au:S/C:N/I:N/A:C
Name of the Vulnerable Software and Affected Versions Siemens SCALANCE X-300 switches versions prior to 4.0 Siemens SCALANCE X 408 switches versions prior to 4.0
Description The issue allows remote authenticated users to cause a denial of service, resulting in a reboot of the system, by sending crafted FTP packets to the FTP server.
Recommendations For Siemens SCALANCE X-300 switches with firmware prior to 4.0, update to version 4.0 or later. For Siemens SCALANCE X 408 switches with firmware prior to 4.0, update to version 4.0 or later.