PT-2018-14609

CVE-2018-18731

·

Publicado

2018-10-28

·

Atualizado

2019-01-29

Descrição por

CVSS 2.0
7.8
Alta
MétricasAV:N/AC:L/Au:N/C:N/I:N/A:C
Name of the Vulnerable Software and Affected Versions Tenda AC7 version 15.03.06.44 CN Tenda AC9 version 15.03.05.19(6318) CN Tenda AC10 version 15.03.06.23 CN Tenda AC15 version 15.03.05.19 CN Tenda AC18 version 15.03.05.19(6318) CN
Description A buffer overflow issue exists in the router's web server, specifically in the httpd. The problem arises when processing the deviceMac parameter for a post request. The value of this parameter is directly used in a sprintf to a local variable on the stack, which overrides the return address of the function.
Recommendations For Tenda AC7 version 15.03.06.44 CN, avoid using the deviceMac parameter in post requests to the httpd web server until a patch is available. For Tenda AC9 version 15.03.05.19(6318) CN, restrict access to the httpd web server to minimize the risk of exploitation. For Tenda AC10 version 15.03.06.23 CN, consider disabling the httpd web server temporarily until a fix is provided. For Tenda AC15 version 15.03.05.19 CN, refrain from using the vulnerable httpd web server until an update is released. For Tenda AC18 version 15.03.05.19(6318) CN, as a temporary workaround, limit the use of the deviceMac parameter in the httpd web server.
Explorabilidade
Exploit
Correção
Impactos
Pesquisadores
Fornecedores
Produtos afetados
Identificadores relacionados
Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾