PT-2018-18008

CVE-2018-7301

·

Publicado

2018-02-22

·

Atualizado

2018-03-18

Descrição por

CVSS 3.1
9.8
Crítica
MétricasAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions eQ-3 AG HomeMatic CCU2 version 2.29.22
Description The issue allows exploitation by sending arbitrary XML-RPC requests to control attached BidCos devices, due to an open XML-RPC port without authentication.
Recommendations For version 2.29.22, consider restricting access to the XML-RPC port to minimize the risk of exploitation. As a temporary workaround, limit control of the attached BidCos devices until a patch is available. At the moment, there is no information about a newer version that contains a fix for this vulnerability.
Impactos
Pesquisadores
Fornecedores
Produtos afetados
Identificadores relacionados
Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾