PT-2018-2977
CVE-2018-13808
·
Publicado
2018-01-08
·
Atualizado
2019-07-11
Descrição por
CVSS 3.1
9.1
CríticaMétricasAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H
Name of the Vulnerable Software and Affected Versions
Siemens CP 1604 versions all
Siemens CP 1616 versions all
Description
The issue is related to the lack of authentication for the Telnet service in the Siemens CP communication module software. This could allow a remote attacker to extract data or cause a denial-of-service condition. The attacker would need network access to port 23/tcp to exploit this issue. At the time of reporting, there were no known public exploits of this issue.
Recommendations
For Siemens CP 1604, restrict access to port 23/tcp to minimize the risk of exploitation.
For Siemens CP 1616, restrict access to port 23/tcp to minimize the risk of exploitation.
Explorabilidade
Correção
Impactos
Fornecedores
Produtos afetados
Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾