PT-2018-6615

CVE-2017-18019

·

Publicado

2018-01-04

·

Atualizado

2018-01-19

Descrição por

CVSS 3.1
7.1
Alta
MétricasAV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H
Name of the Vulnerable Software and Affected Versions: K7 Total Security versions prior to 15.1.0.305
Description: The issue arises from insufficient sanitization of user-controlled input to the K7Sentry device, allowing the input to compare an arbitrary memory address with a fixed value. This can be exploited to read the contents of arbitrary memory. Additionally, the product crashes when a DeviceIoControl call is made to the K7Sentry device with an invalid kernel pointer.
Recommendations: For versions prior to 15.1.0.305, update to version 15.1.0.305 or later to resolve the issue. As a temporary workaround, consider restricting access to the K7Sentry device to minimize the risk of exploitation.
Explorabilidade
Exploit
Correção
Impactos
Fornecedores
Produtos afetados
Enumeração de fraquezas
Identificadores relacionados
Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾