PT-2019-12745
CVE-2019-12310
·
Publicado
2019-06-03
·
Atualizado
2019-06-04
Descrição por
CVSS 3.1
9.8
CríticaMétricasAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions
ExaGrid appliances version v4.8.1.1044.P50
Description
The issue allows remote attackers to view and retrieve verbose logging information due to a directory traversal vulnerability in the /monitor/data/Upgrade/ directory. This vulnerability can lead to the exposure of sensitive run-time information, including Base64 encoded 'support' credentials, which can result in administrative access to the device.
Recommendations
For version v4.8.1.1044.P50, as a temporary workaround, consider restricting access to the /monitor/data/Upgrade/ directory until a patch is available. Avoid using the
support credentials in the affected device until the issue is resolved. At the moment, there is no information about a newer version that contains a fix for this vulnerability.Explorabilidade
Exploit
Impactos
Pesquisadores
Fornecedores
Produtos afetados
Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾