PT-2019-6902

CVE-2013-2807

·

Publicado

2019-03-26

·

Atualizado

2020-02-10

Descrição por

CVSS 2.0
7.8
Alta
MétricasAV:N/AC:L/Au:N/C:N/I:N/A:C
Name of the Vulnerable Software and Affected Versions Rockwell Automation RSLinx Enterprise Software versions CPR9 through CPR9-SR6
Description The issue arises from incorrect handling of input, resulting in a logic error when calculating the Total Record Size field. This can be exploited by sending a modified datagram to the service over Port 4444/UDP, specifically by altering the Record Data Size field to an oversized value. This causes the service to calculate an undersized Total Record Size, leading to an out-of-bounds read access violation and subsequent service crash. The service can be recovered with a manual reboot.
Recommendations For versions CPR9 through CPR9-SR6, refer to the Rockwell Automation Security Advisory for patches and detailed information on resolving the issue.
Explorabilidade
Correção
Impactos
Fornecedores
Produtos afetados
Identificadores relacionados
Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾