PT-2023-23441 · Linksys · Linksys E2000

CVE-2023-31740

·

Publicado

2023-05-23

·

Atualizado

2025-01-21

CVSS v3.1

7.2

Alta

VetorAV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions Linksys E2000 router version 1.0.06
Description The issue is related to a command injection vulnerability. If an attacker gains web management privileges, they can inject commands into the post request parameters WL atten bb, WL atten radio, and WL atten ctl in the "apply.cgi" interface, thereby gaining shell privileges.
Recommendations For version 1.0.06, consider disabling the web management interface until a patch is available. Restrict access to the "apply.cgi" interface to minimize the risk of exploitation. Avoid using the parameters WL atten bb, WL atten radio, and WL atten ctl in the affected interface until the issue is resolved. At the moment, there is no information about a newer version that contains a fix for this vulnerability.

Exploit

Command Injection

Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾

Enumeração de Fraquezas

Identificadores relacionados

CVE-2023-31740

Produtos afetados

Linksys E2000