PT-2023-27970 · Tenda · Tenda Ac9+1
CVE-2023-41552
·
Publicado
2023-08-30
·
Atualizado
2023-08-31
CVSS v3.1
9.8
Crítica
| Vetor | AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
Name of the Vulnerable Software and Affected Versions
Tenda AC7 version V15.03.06.44
Tenda AC9 version V15.03.06.42 multi
Description
A stack overflow issue was discovered, which occurs via the
ssid parameter at the "/goform/fast setting wifi set" API endpoint.Recommendations
For Tenda AC7 version V15.03.06.44, avoid using the
ssid parameter in the "/goform/fast setting wifi set" API endpoint until the issue is resolved.
For Tenda AC9 version V15.03.06.42 multi, avoid using the ssid parameter in the "/goform/fast setting wifi set" API endpoint until the issue is resolved.
As a temporary workaround, consider restricting access to the "/goform/fast setting wifi set" API endpoint to minimize the risk of exploitation.Exploit
Correção
Memory Corruption
Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾
Enumeração de Fraquezas
Identificadores relacionados
Produtos afetados
Tenda Ac7
Tenda Ac9