PT-2023-8292

CVE-2023-4464

·

Publicado

2023-12-29

·

Atualizado

2024-05-17

Descrição por

CVSS 2.0
8.3
Alta
MétricasAV:N/AC:L/Au:M/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions Poly Trio 8300 versions prior to the fixed version Poly Trio 8500 versions prior to the fixed version Poly Trio 8800 versions prior to the fixed version Poly Trio C60 versions prior to the fixed version Poly CCX 350 versions prior to the fixed version Poly CCX 400 versions prior to the fixed version Poly CCX 500 versions prior to the fixed version Poly CCX 505 versions prior to the fixed version Poly CCX 600 versions prior to the fixed version Poly CCX 700 versions prior to the fixed version Poly EDGE E100 versions prior to the fixed version Poly EDGE E220 versions prior to the fixed version Poly EDGE E300 versions prior to the fixed version Poly EDGE E320 versions prior to the fixed version Poly EDGE E350 versions prior to the fixed version Poly EDGE E400 versions prior to the fixed version Poly EDGE E450 versions prior to the fixed version Poly EDGE E500 versions prior to the fixed version Poly EDGE E550 versions prior to the fixed version Poly VVX 101 versions prior to the fixed version Poly VVX 150 versions prior to the fixed version Poly VVX 201 versions prior to the fixed version Poly VVX 250 versions prior to the fixed version Poly VVX 300 versions prior to the fixed version Poly VVX 301 versions prior to the fixed version Poly VVX 310 versions prior to the fixed version Poly VVX 311 versions prior to the fixed version Poly VVX 350 versions prior to the fixed version Poly VVX 400 versions prior to the fixed version Poly VVX 401 versions prior to the fixed version Poly VVX 410 versions prior to the fixed version Poly VVX 411 versions prior to the fixed version Poly VVX 450 versions prior to the fixed version Poly VVX 500 versions prior to the fixed version Poly VVX 501 versions prior to the fixed version Poly VVX 600 versions prior to the fixed version Poly VVX 601 versions prior to the fixed version
Description The issue affects some unknown processing of the component Diagnostic Telnet Mode, leading to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Recommendations To resolve the issue for each affected version, it is recommended to upgrade the affected component. As a temporary workaround, consider disabling the Diagnostic Telnet Mode until a patch is available. Restrict access to the Diagnostic Telnet Mode to minimize the risk of exploitation. Avoid using the Diagnostic Telnet Mode in the affected devices until the issue is resolved. At the moment, there is no information about a newer version that contains a fix for this vulnerability.
Explorabilidade
Exploit
Impactos
Fornecedores
Produtos afetados
Identificadores relacionados
Encontrou algum problema na descrição? Tem algo a acrescentar? Fique à vontade para nos escrever 👾