PT-2015-7806

CVE-2015-8561

·

Published

2015-12-08

·

Updated

2015-12-16

Description by

CVSS 2.0
6.8
Medium
MetricsAV:N/AC:M/Au:N/C:P/I:P/A:P
Name of the Vulnerable Software and Affected Versions Schneider Electric ProClima versions prior to 6.2
Description The issue allows remote attackers to execute arbitrary code or cause a denial of service due to memory corruption. This can be achieved by providing a crafted integer value to certain methods in the F1BookView ActiveX control, including the AttachToSS, CopyAll, CopyRange, CopyRangeEx, or SwapTable method.
Recommendations For versions prior to 6.2, update to version 6.2 or later to resolve the issue. As a temporary workaround, consider disabling the AttachToSS, CopyAll, CopyRange, CopyRangeEx, and SwapTable methods in the F1BookView ActiveX control until a patch is available.
Exploitability
Fix
Impacts
Researchers
Vendors
Affected products
Related identifiers
ZDI-15-626
ZDI-15-627
ZDI-15-628
ZDI-15-629
Found an issue in the description? Have something to add? Feel free to write us 👾