PT-2016-3201

CVE-2016-1560

·

Published

2016-01-26

·

Updated

2017-04-27

Description by

CVSS 2.0
10
Critical
MetricsAV:N/AC:L/Au:N/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions ExaGrid appliances with firmware before 4.8 P26
Description The issue is related to the use of default credentials in ExaGrid backup devices' firmware. Exploitation of this issue may allow a remote attacker to gain root access to the device using the default password 'inflection' for the root account via SSH or HTTP protocols. This could potentially allow administrative access to the device.
Recommendations For ExaGrid appliances with firmware before 4.8 P26, update the firmware to version 4.8 P26 or later to change the default password for the root shell account and remove support for the default support account in the web interface. As a temporary workaround, consider changing the default password for the root account and disabling the support account in the web interface until a firmware update can be applied.
Exploitability
Exploit
Fix
Impacts
Researchers
Vendors
Affected products
Related identifiers
Found an issue in the description? Have something to add? Feel free to write us 👾