PT-2016-7208
CVE-2016-7090
·
Published
2016-09-29
·
Updated
2016-11-28
Description by
CVSS 2.0
4.3
MediumMetricsAV:N/AC:M/Au:N/C:P/I:N/A:N
Name of the Vulnerable Software and Affected Versions
Siemens SCALANCE M-800 and S615 modules versions prior to 4.02
Description
The issue concerns the integrated web server's handling of session cookies in https sessions. Specifically, it does not set the secure flag for the session cookie, making it easier for remote attackers to capture this cookie by intercepting its transmission within an http session.
Recommendations
For versions prior to 4.02, update the firmware to version 4.02 or later to resolve the issue. As a temporary workaround, consider restricting access to the web server to minimize the risk of exploitation.
Found an issue in the description? Have something to add? Feel free to write us 👾