PT-2017-3482

CVE-2017-12495

·

Published

2017-08-11

·

Updated

2018-02-23

Description by

CVSS 2.0
9.0
High
MetricsAV:N/AC:L/Au:S/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions HPE Intelligent Management Center (iMC) PLAT version PLAT 7.3 (E0504)
Description A Remote Code Execution issue was discovered, related to insufficient input validation in the selectUserGroup.xhtml component. This allows a remote attacker to execute arbitrary code using the beanName parameter.
Recommendations For HPE Intelligent Management Center PLAT version PLAT 7.3 (E0504), update to HPE Intelligent Management Center PLAT v7.3 (E0506) or any subsequent version to resolve the issue. As a temporary workaround, consider restricting access to the selectUserGroup.xhtml component to minimize the risk of exploitation.
Exploitability
Fix
Impacts
Vendors
Affected products
Related identifiers
Found an issue in the description? Have something to add? Feel free to write us 👾