PT-2018-18276
CVE-2018-7780
·
Published
2018-07-03
·
Updated
2019-05-24
Description by
CVSS 3.1
9.8
CriticalMetricsAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions:
Schneider Electric Pelco Sarix Professional 1st generation cameras versions prior to 3.29.69
Description:
A buffer overflow issue exists in the cgi program "set" of the affected cameras.
Recommendations:
For versions prior to 3.29.69, update to version 3.29.69 or later to resolve the issue.
Found an issue in the description? Have something to add? Feel free to write us 👾