PT-2018-6615

CVE-2017-18019

·

Published

2018-01-04

·

Updated

2018-01-19

Description by

CVSS 3.1
7.1
High
MetricsAV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H
Name of the Vulnerable Software and Affected Versions: K7 Total Security versions prior to 15.1.0.305
Description: The issue arises from insufficient sanitization of user-controlled input to the K7Sentry device, allowing the input to compare an arbitrary memory address with a fixed value. This can be exploited to read the contents of arbitrary memory. Additionally, the product crashes when a DeviceIoControl call is made to the K7Sentry device with an invalid kernel pointer.
Recommendations: For versions prior to 15.1.0.305, update to version 15.1.0.305 or later to resolve the issue. As a temporary workaround, consider restricting access to the K7Sentry device to minimize the risk of exploitation.
Exploitability
Exploit
Fix
Impacts
Vendors
Affected products
Related identifiers