PT-2019-12408

CVE-2019-11601

·

Published

2019-08-21

·

Updated

2023-02-02

Description by

CVSS 3.1
9.1
Critical
MetricsAV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H
Name of the Vulnerable Software and Affected Versions ProSyst mBS SDK versions prior to 8.2.6 Bosch IoT Gateway Software versions prior to 9.2.0
Description A directory traversal issue exists in the remote access to backup and restore functionality, allowing remote attackers to write or delete files at any location.
Recommendations For ProSyst mBS SDK versions prior to 8.2.6, update to version 8.2.6 or later to resolve the issue. For Bosch IoT Gateway Software versions prior to 9.2.0, update to version 9.2.0 or later to resolve the issue.