PT-2019-6900
CVE-2013-2805
·
Published
2019-03-26
·
Updated
2020-02-10
Description by
CVSS 2.0
7.8
HighMetricsAV:N/AC:L/Au:N/C:N/I:N/A:C
Name of the Vulnerable Software and Affected Versions
Rockwell Automation RSLinx Enterprise Software versions CPR9 through CPR9-SR6
Description
The issue arises from incorrect handling of input by the LogReceiver.exe service, resulting in a logic error when it receives a datagram with an incorrect value in the
Record Data Size field. An attacker can exploit this by sending a modified datagram over Port 4444/UDP, causing an out-of-bounds read access violation that leads to a service crash. The service can be recovered with a manual reboot.Recommendations
For versions CPR9 through CPR9-SR6, apply the patches and follow the details provided in the Rockwell Automation Security Advisory to resolve the issue. As a temporary workaround, consider restricting access to Port 4444/UDP to minimize the risk of exploitation.
Found an issue in the description? Have something to add? Feel free to write us 👾