PT-2020-6367

CVE-2020-7520

·

Published

2020-07-14

·

Updated

2020-07-28

Description by

CVSS 2.0
6.8
Medium
MetricsAV:N/AC:H/Au:S/C:P/I:C/A:C
Name of the Vulnerable Software and Affected Versions Schneider Electric Software Update (SESU) versions 2.4.0 and prior
Description A URL redirection to untrusted site issue exists, which could lead to the execution of malicious code on the victim's machine. To exploit this, an attacker needs privileged access to modify a Windows registry key, diverting traffic updates through a server they control, and then uses a man-in-the-middle attack to complete the exploit. The vulnerability can allow a remote attacker to execute arbitrary code.
Recommendations For versions 2.4.0 and prior, as a temporary workaround, consider restricting access to the Windows registry key that can be modified to divert traffic updates, until a patch is available. Additionally, restrict access to the engineering workstation to prevent privileged access. At the moment, there is no information about a newer version that contains a fix for this vulnerability.
Impacts
Vendors
Affected products
Related identifiers
Found an issue in the description? Have something to add? Feel free to write us 👾