PT-2021-15206 · Schneider Electric · Powerlogic Egx300+1

CVE-2021-22768

·

Published

2021-06-11

·

Updated

2024-08-03

CVSS v3.1

9.8

Critical

VectorAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions PowerLogic EGX100 versions 3.0.0 and newer PowerLogic EGX300 (all versions)
Description A vulnerability exists due to improper input validation, potentially causing denial of service or remote code execution via a specially crafted HTTP packet.
Recommendations For PowerLogic EGX100 versions 3.0.0 and newer, update to a version that includes a fix for the improper input validation issue. For PowerLogic EGX300, apply configuration changes to restrict access to vulnerable HTTP endpoints until a patch is available. As a temporary workaround, consider restricting access to the device to minimize the risk of exploitation.

Fix

RCE

Found an issue in the description? Have something to add? Feel free to write us 👾

Weakness Enumeration

Related Identifiers

CVE-2021-22768

Affected Products

Powerlogic Egx100
Powerlogic Egx300