PT-2021-18617
CVE-2021-30126
·
Published
2021-04-02
·
Updated
2021-04-09
Description by
CVSS 3.1
6.5
MediumMetricsAV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N
Name of the Vulnerable Software and Affected Versions
Lightmeter ControlCenter versions 1.1.0 through 1.5.x before 1.5.1
Description
The issue allows unauthorized access to application settings, potentially including sensitive information such as SMTP passwords and Slack access tokens, in publicly available Lightmeter instances. This is achieved via a settings HTTP query when the URL of the instance is known.
Recommendations
For Lightmeter ControlCenter versions 1.1.0 through 1.5.x before 1.5.1, update to version 1.5.1 or later to resolve the issue. As a temporary workaround, consider restricting access to the settings HTTP query to minimize the risk of exploitation.
Found an issue in the description? Have something to add? Feel free to write us 👾