PT-2021-22104

CVE-2021-38390

·

Published

2021-08-30

·

Updated

2021-09-07

Description by

CVSS 2.0
10
Critical
MetricsAV:N/AC:L/Au:N/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions Delta Electronics DIAEnergie versions 1.7.5 and prior
Description A Blind SQL injection issue exists due to improper validation of the user-controlled value supplied through the egyid parameter in the "/DataHandler/HandlerEnergyType.ashx" endpoint. This allows a remote, unauthenticated attacker to execute arbitrary code in the context of NT SERVICEMSSQLSERVER.
Recommendations For Delta Electronics DIAEnergie versions 1.7.5 and prior, consider restricting access to the "/DataHandler/HandlerEnergyType.ashx" endpoint until a patch is available. As a temporary workaround, avoid using the egyid parameter in the affected endpoint to minimize the risk of exploitation. At the moment, there is no information about a newer version that contains a fix for this issue.
Exploitability
Fix
Impacts
Researchers
Vendors
Affected products
Related identifiers