PT-2021-22573
CVE-2021-39375
·
Published
2021-08-24
·
Updated
2021-09-14
Description by
CVSS 3.1
8.8
HighMetricsAV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions:
Philips Healthcare Tasy Electronic Medical Record (EMR) version 3.06
Description:
The issue allows SQL injection via specific parameters. For the WAdvancedFilter/getDimensionItemsByCode endpoint, the
FilterValue parameter is vulnerable. Additionally, the CorCad F2/executaConsultaEspecifico endpoint is affected, specifically the IE CORPO ASSIST or CD USUARIO CONVENIO parameters.Recommendations:
For version 3.06, consider restricting access to the WAdvancedFilter/getDimensionItemsByCode endpoint and the CorCad F2/executaConsultaEspecifico endpoint to minimize the risk of exploitation. Avoid using the
FilterValue parameter in the WAdvancedFilter/getDimensionItemsByCode endpoint and the IE CORPO ASSIST or CD USUARIO CONVENIO parameters in the CorCad F2/executaConsultaEspecifico endpoint until the issue is resolved.
At the moment, there is no information about a newer version that contains a fix for this vulnerability.Exploitability
Exploit
Impacts
Researchers
Vendors
Affected products
Found an issue in the description? Have something to add? Feel free to write us 👾