PT-2021-22574
CVE-2021-39376
·
Published
2021-08-24
·
Updated
2021-08-31
Description by
CVSS 3.1
8.8
HighMetricsAV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions:
Philips Healthcare Tasy Electronic Medical Record (EMR) version 3.06
Description:
The issue allows SQL injection via the CorCad F2/executaConsultaEspecifico endpoint, specifically through the
IE CORPO ASSIST or CD USUARIO CONVENIO parameters. This could potentially lead to unauthorized access or manipulation of sensitive data.Recommendations:
For version 3.06, consider restricting access to the CorCad F2/executaConsultaEspecifico endpoint until a patch is available. As a temporary workaround, avoid using the
IE CORPO ASSIST or CD USUARIO CONVENIO parameters in the affected endpoint to minimize the risk of exploitation. At the moment, there is no information about a newer version that contains a fix for this vulnerability.Exploitability
Exploit
Impacts
Researchers
Vendors
Affected products
Found an issue in the description? Have something to add? Feel free to write us 👾