PT-2022-21872

CVE-2022-3382

·

Published

2022-10-17

·

Updated

2022-10-21

Description by

CVSS 3.1
7.5
High
MetricsAV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Name of the Vulnerable Software and Affected Versions HIWIN Robot System Software version 3.3.21.9869
Description The issue arises from the software's failure to properly address the terminated command source. This allows an attacker to craft code that can disconnect the HIWIN Robot System Software (HRSS) and the controller, resulting in a denial-of-service condition.
Recommendations For HIWIN Robot System Software version 3.3.21.9869, consider temporarily restricting access to the command source to minimize the risk of exploitation until a patch is available. At the moment, there is no information about a newer version that contains a fix for this vulnerability.