PT-2022-22987
CVE-2022-35876
·
Published
2022-10-25
·
Updated
2022-10-28
Description by
CVSS 3.1
9.8
CriticalMetricsAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions
Abode Systems, Inc. iota All-In-One Security Kit versions 6.9X and 6.9Z
Description
The issue arises from format string injection via the
default key id and key configuration parameters within the testWifiAP XCMD handler. Specially-crafted configuration values can lead to memory corruption, information disclosure, and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.Recommendations
For versions 6.9X and 6.9Z, consider restricting access to the
testWifiAP XCMD handler until a patch is available. As a temporary workaround, avoid using the default key id and key configuration parameters in the affected XCMD handler to minimize the risk of exploitation.Exploitability
Exploit
Fix
Impacts
Vendors
Affected products
Found an issue in the description? Have something to add? Feel free to write us 👾