PT-2023-9148
CVE-2023-51637
·
Published
2023-11-29
·
Updated
2025-08-14
Description by
CVSS 2.0
10
CriticalMetricsAV:N/AC:L/Au:N/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions
Sante PACS Server PG (affected versions not specified)
Description
This issue allows remote attackers to execute arbitrary code on affected installations of Sante PACS Server PG. Authentication is not required to exploit this issue. The specific flaw exists within the implementation of the DICOM service, which listens on TCP port 11122 by default. When parsing the
NAME element of the PATIENT record, the process does not properly validate a user-supplied string before using it to construct SQL queries. An attacker can leverage this issue to execute code in the context of NETWORK SERVICE.Recommendations
At the moment, there is no information about a newer version that contains a fix for this issue.
Found an issue in the description? Have something to add? Feel free to write us 👾