PT-2024-17165
CVE-2024-11656
·
Published
2024-11-25
·
Updated
2024-12-10
Description by
CVSS 3.1
7.2
HighMetricsAV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions
EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118
Description
A critical issue has been found in the processing of the file
/admin/network/diag ping6. The manipulation of the argument diag ping6 leads to command injection. This issue can be exploited remotely. The exploit has been disclosed to the public. The vendor was contacted about this disclosure but did not respond.Recommendations
For EnGenius ENH1350EXT, ENS500-AC and ENS620EXT up to 20241118, as a temporary workaround, consider restricting access to the
/admin/network/diag ping6 file to minimize the risk of exploitation. Avoid using the argument diag ping6 in the affected file until the issue is resolved. At the moment, there is no information about a newer version that contains a fix for this vulnerability.Exploitability
Exploit
Impacts
Vendors
Affected products
Found an issue in the description? Have something to add? Feel free to write us 👾