PT-2024-20649

CVE-2024-24897

·

Published

2024-03-15

·

Updated

2024-03-26

Description by

CVSS 3.1
8.1
High
MetricsAV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions openEuler A-Tune-Collector versions 1.1.0-3 through 1.3.0
Description The issue is related to an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. This vulnerability allows Command Injection in openEuler A-Tune-Collector on Linux. The vulnerability is associated with program files atune collector/plugin/monitor/process/sched.py.
Recommendations For versions 1.1.0-3 through 1.3.0, consider disabling the vulnerable sched.py module until a patch is available. Restrict access to the vulnerable atune collector plugin to minimize the risk of exploitation. Avoid using the process monitor functionality in the affected API endpoints until the issue is resolved. At the moment, there is no information about a newer version that contains a fix for this vulnerability.
Impacts
Researchers
Vendors
Affected products
Related identifiers
OESA-2024-1271
OESA-2024-1272
OESA-2024-1273
OESA-2024-1274
Found an issue in the description? Have something to add? Feel free to write us 👾