PT-2024-4783
CVE-2024-4111
·
Published
2024-04-16
·
Updated
2024-06-04
Description by
CVSS 2.0
9.0
HighMetricsAV:N/AC:L/Au:S/C:C/I:C/A:C
Name of the Vulnerable Software and Affected Versions:
Tenda TX9 version 22.03.02.10
Description:
A critical issue has been found, affecting the function
sub 42BD7C of the file /goform/SetLEDCfg. The manipulation of the argument time leads to a stack-based buffer overflow. This issue can be exploited remotely by sending a specially crafted POST request with the time parameter. The exploit has been disclosed publicly.Recommendations:
For Tenda TX9 version 22.03.02.10, as a temporary workaround, consider disabling the
sub 42BD7C function until a patch is available. Restrict access to the /goform/SetLEDCfg file to minimize the risk of exploitation. Avoid using the time parameter in the affected API endpoint until the issue is resolved.
At the moment, there is no information about a newer version that contains a fix for this vulnerability.Exploitability
Exploit
Impacts
Vendors
Affected products
Found an issue in the description? Have something to add? Feel free to write us 👾