PT-2025-20456

CVE-2025-4453

·

Published

2025-05-08

·

Updated

2025-05-13

Description by

CVSS 3.1
9.8
Critical
MetricsAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions D-Link DIR-619L version 2.04B04
Description A critical issue affects the formSysCmd function, where manipulation of the sysCmd argument leads to command injection. This can be initiated remotely. The vendor was contacted about this disclosure. This issue only affects products that are no longer supported by the maintainer.
Recommendations For D-Link DIR-619L version 2.04B04, as a temporary workaround, consider disabling the formSysCmd function until a patch is available. Restrict access to the sysCmd argument to minimize the risk of exploitation. At the moment, there is no information about a newer version that contains a fix for this vulnerability.
Found an issue in the description? Have something to add? Feel free to write us 👾