PT-2025-3924

CVE-2025-0497

·

Published

2025-01-15

·

Updated

2025-01-30

Description by

CVSS 3.1
9.8
Critical
MetricsAV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions Rockwell Automation FactoryTalk AssetCentre versions prior to V15.00.001
Description A data exposure issue exists due to the storage of credentials in the configuration file of packages such as EventLogAttachmentExtractor, ArchiveExtractor, LogCleanUp, or ArchiveLogCleanUp. This allows an attacker to potentially disclose protected information.
Recommendations For versions prior to V15.00.001, consider updating to V15.00.001 or later to resolve the issue. As a temporary workaround, restrict access to the configuration files of the affected packages to minimize the risk of exploitation. Avoid using the affected packages until the issue is resolved.
Exploitability
Fix
Impacts
Researchers
Vendors
Affected products
Related identifiers
Found an issue in the description? Have something to add? Feel free to write us 👾