PT-2026-103896

CVE-2026-103004

·

Published

2026-10-01

·

Updated

2026-10-30

Description by

CVSS 4.0
6.3
Medium
MetricsAV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N
Name of the Vulnerable Software and Affected Versions Next.js versions 16.3.0 through 16.3.7
Description When Cache Components are enabled via cacheComponents: true, use cache handlers using next/root-params may leak return values to pages with different root parameters. This occurs when a use cache function calls another use cache function that reads a root param; if the inner call is served from an existing entry, the enclosing function's cache key may omit that root param. Consequently, the enclosing entry is written once and reused across all root param values, potentially serving content produced for a different value regardless of whether the page is prerendered at build time, at runtime, or rendered dynamically. Shared cache headers may further redistribute this content to downstream caches. The leaked values are not attacker-controlled, and the content served depends on which invocation wrote the entry first.
Recommendations Update to version 16.3.8.
Exploitability
Exploit
Fix
Vendors
Affected products
Related identifiers
GHSA-H694-7CP9-M8P3
CLEANSTART-2026-MS47438
CLEANSTART-2026-SE76644
Found an issue in the description? Have something to add? Feel free to write us 👾