PT-2026-107784 · Brocade · Fabric Os
CVE-2026-87672
·
Published
2026-10-08
·
Updated
2026-10-08
CVSS v4.0
6.8
Medium
| Vector | AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N |
An information disclosure vulnerability exists in the SupportLink diagnostic collection utilities of Brocade Fabric OS versions before 10.0.1. When SupportLink is configured to use an authenticated HTTP proxy, the system stores the full proxy URL. Anyone with access to the diagnostic support bundle, such as support personnel or users with access to file shares where support bundles are stored, can extract these cleartext proxy credentials.
Fix
Insertion into Log File
Found an issue in the description? Have something to add? Feel free to write us 👾
Weakness Enumeration
Related Identifiers
Affected Products
Fabric Os