PT-2026-137704

CVE-2026-104136

·

Published

2026-11-05

·

Updated

2026-11-05

Description by

CVSS 4.0
7.1
High
MetricsAV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
Name of the Vulnerable Software and Affected Versions OpenEMR versions prior to 8.3.0
Description An issue exists in the new recall branch of the 'interface/main/messages/save.php' endpoint where the system accepts a caller-supplied pid without enforcing patient-level or recall-workflow authorization. This allows a low-privilege authenticated user who knows or enumerates a patient identifier to retrieve sensitive data, including patient details, contact fields, HIPAA notification preferences, recent appointment information, and existing recall information.
Recommendations Update to version 8.3.0.
Exploitability
Exploit
Fix
Impacts
Researchers