PT-2026-141144
CVE-2026-114031
·
Published
2026-11-09
·
Updated
2026-11-09
Description by
CVSS 3.1
7.8
HighMetricsAV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Name of the Vulnerable Software and Affected Versions
Illumio VEN for Windows (affected versions not specified)
Description
Incorrect permission assignment in the VEN installer allows local privilege escalation to SYSTEM. The installer grants LOCAL SERVICE full access to VEN data and installation folders. Because the SYSTEM-privileged
illumio-ven-ctl component reads and trusts the configuration and state files within these folders, an attacker with code execution as NT AUTHORITYLOCAL SERVICE can modify the VEN configuration to force illumio-ven-ctl to execute an injected command with SYSTEM privileges.Recommendations
At the moment, there is no information about a newer version that contains a fix for this vulnerability.
Found an issue in the description? Have something to add? Feel free to write us 👾