PT-2026-141570
CVE-2026-120295
·
Published
2026-11-10
·
Updated
2026-11-12
Description by
CVSS 4.0
7.1
HighMetricsAV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N
Name of the Vulnerable Software and Affected Versions
nerves hub versions 1.0.0 through 2.5.2
Description
An incorrect authorization issue in the devices page bulk move feature of nerves hub web allows an authenticated user with the
manage role in one organization and only the view role in another to move devices into the second organization's product using the "Move device(s) to product" action. This occurs because the target-product event in NervesHubWeb.Live.Devices.Index uses the NervesHub.Products.get by id/2 function, which only verifies that the user is a member of the product's organization regardless of their role. Subsequently, the move-devices-product action calls NervesHub.Devices.BulkActions.move many/3 and Devices.move/3 to change the org id and product id of the selected devices without verifying if the user has the required manage role in the target organization.As a result, a moved device retains its key and certificate, joins the target organization's matching deployment groups, and receives the target organization's firmware via a download URL, which a user with only the
view role would otherwise be unable to obtain. The user cannot modify or control devices that already belong to the target organization.Recommendations
Update nerves hub to version 2.5.3 or later.
After upgrading, review the
audit logs for resource type NervesHub.Products.Product with descriptions containing "moved device" to identify and remove devices moved by users who did not hold the manage or admin role in the target organization.Exploitability
Exploit
Fix
Impacts
Vendors
Affected products
Found an issue in the description? Have something to add? Feel free to write us 👾