PT-2026-148234
CVE-2026-121192
·
Published
2026-11-16
·
Updated
2026-11-16
Description by
CVSS 3.1
6.8
MediumMetricsAV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N
Name of the Vulnerable Software and Affected Versions
@fastify/proxy-addr versions 3.0.0 through 5.1.2
Description
When the
trustProxy setting is configured with a zoned IPv6 link-local address, the software ignores the zone identifier during trust comparison and only checks the address bits. On a multi-homed server, this allows a host on a different link with the same link-local address to be incorrectly trusted. An attacker in this position can spoof the X-Forwarded-For, X-Forwarded-Host, and X-Forwarded-Proto headers, allowing them to manipulate the client IP, host, and protocol reported by Fastify. This can bypass IP allowlists, rate limiting, and audit logging.Recommendations
Update @fastify/proxy-addr to version 5.1.3 or later.
As a temporary workaround, avoid trusting a zoned link-local address on a multi-homed host and use a global, private, or loopback proxy address instead.